Harmonics can significantly affect the measurement of inductance because practical inductors do not have the same impedance at all frequencies. When a voltage or current waveform contains harmonic components, each harmonic experiences a different inductive reactance, , so the measured voltage, current, and phase angle may no longer represent the fundamental-frequency inductance accurately. Core losses, winding resistance, skin effect, proximity effect, and magnetic saturation can also vary with frequency, causing the apparent inductance to change. As a result, instruments measuring inductance from distorted waveforms may indicate an erroneous value, particularly when higher-order harmonics are significant. For accurate measurement, a clean sinusoidal test signal at a specified frequency should preferably be used, and harmonic distortion should be minimized or filtered.
Harmonics and Inductance Measurement
1. Simulation Controls
2. Electrical Principle
For a pure sinusoidal test signal, the instrument can determine inductance from the voltage, current and phase relationship at the specified frequency. When harmonics are present, however, each harmonic sees a different inductive reactance because XL = 2πfL.
3. Waveform Display
4. Harmonic Components
5. Measurement Results
6. What the Simulation Demonstrates
7. Why Harmonics Affect Practical Inductors
Core losses: Higher-frequency components can increase magnetic core losses.
Skin effect: Higher-frequency current tends to concentrate toward the surface of the conductor, increasing effective winding resistance.
Proximity effect: Magnetic fields from nearby conductors can further increase AC resistance.
Saturation: Large waveform peaks can move the magnetic core toward saturation, making the effective inductance nonlinear.
Result: An inductance meter exposed to a significantly distorted waveform may obtain a value that does not represent the inductance measured with a clean, specified-frequency sinusoidal test signal.